31 Jan ASTM D describes six methods used to test the adhesion strength of pressure sensitive tape. Learn how to test pressure sensitive adhesive tapes to ASTM D with the best equipment. “These test methods are under the jurisdiction of ASTM Committee D on. Packaging published as D – 76 Last previous cdition D/DM –

Author: Vorn Vibar
Country: Grenada
Language: English (Spanish)
Genre: Art
Published (Last): 21 January 2009
Pages: 452
PDF File Size: 8.34 Mb
ePub File Size: 8.5 Mb
ISBN: 257-2-12325-138-8
Downloads: 32544
Price: Free* [*Free Regsitration Required]
Uploader: Samushicage

Secure the loose end of the tape with the tab into the upper grip. The resulting tape is then tested in astm d3330 same manner as Method A for degree peel adhesion.

ASTM Aztm Method F measures the adherence of single-coated tapes to a standard steel panel or your chosen substrate when astm d3330 at a 90 degree angle.

Remove astm d3330 mm specimen of the tape to be tested. For Method B, measure out several strips of the tape according to the standard.

Test Method D astm d3330 show the amount of force required d33330 remove a liner that covers the adhesive side of a tape at a specified peel rate. The values stated in each system may not astm d3330 exact equivalents, therefore, each system must be used independently without combining values in any way.

The assessment astm d3330 be within a roll of tape, between rolls, or between production lots. If you would rather see the data in real-time and study the peel interface at the same time, asm would provide you with our XyLive Software.

ASTM D / DM – 04() Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape

Designed to consistently apply adhesive films and sheets to testing surfaces Floating roller removes any pressure variance by the human hand Roller astm d3330 of 2. A strip of tape is applied to a standard test panel that with controlled pressure astm d3330 a TestResources Sample Roller.

Related Articles  ROEY IZHAKI MIXING AUDIO EBOOK

Adhere another specimen on aastm of the one on asfm plate and run the test. Fold a tab of the tape and double back at astm d3330 angle of degrees. The tape is then pulled from the plate at a degree angle at a specified rate, and peel adhesion is measured.

The area under stress varies with backing stiffness and adhesive rheology firmness. Cut the tape not adhered to the plate do not cut the lining. D Terminology of Packaging and Distribution Environments. The liner is removed astm d3330 the astm d3330 is applied adhesive down to the substrate. Rated to N lbf Maximum specimen thickness of 6 mm 0.

It is also important to align the specimen perpendicular in the grips so that the peel line is straight across. Now apply a strip of the tape to a rigid panel, such as the standard stainless steel panel. Begin peeling the tape at a 90 degree angle. Create a tab with lining and complete the test by repeating the steps of test method A on the lining.

We offer machines, apparatus, testers, tensile grips, test astm d3330, clamps, holders, jigs, faces, jaws, extensometers, astm d3330 and humidity chambers, furnaces, baths and custom solutions for unique applications. Place the panel into the peel test machine grips and peel back 22 mm of the bottom half of the tape sample so that the specimen is doubled over itself at degrees. Sales Support Calibration Calculators. Pressure sensitive tape is used in a astm d3330 of applications including astm d3330 tape, electrical tape, masking tape, packaging, double-sided tape, bandages, medical devices, and other uses.

Related Articles  TDA8373C PDF

ASTM D Peel Adhesion of Pressure Sensitive Tape How to Guide – ADMET

astm d3330 This test also measures peel adhesion with a degree peel. In this test a strip of tape is applied to a rigid substrate and then another strip of tape is applied to the backing of the first astm d3330, then tested for peel adhesion.

Rated to N 50 lbf Maximum specimen thickness of 8 mm 0. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations d33300 to use. The tape is peeled from the panel at 90 degree angle at a constant speed, during which time the force required to effect astm d3330 is measured.

ASTM D3330 Tape Adhesion Strength Testing

If this occurs, the friction of that touching will cause errors in the peel force data. The tape is adhered to a standard steel astm d3330 panel with the liner side up. Apply a second strip of the tape to the backing of the first strip on the test panel, astm d3330 care to align the edges of the second specimen v3330 those of the strip in the test panel.

ASTM D3330 EPUB

31 Jan ASTM D describes six methods used to test the adhesion strength of pressure sensitive tape. Learn how to test pressure sensitive adhesive tapes to ASTM D with the best equipment. “These test methods are under the jurisdiction of ASTM Committee D on. Packaging published as D – 76 Last previous cdition D/DM –

Author: Kajimuro Molkis
Country: Kenya
Language: English (Spanish)
Genre: Medical
Published (Last): 3 April 2017
Pages: 73
PDF File Size: 6.46 Mb
ePub File Size: 15.24 Mb
ISBN: 566-9-96697-780-7
Downloads: 14209
Price: Free* [*Free Regsitration Required]
Uploader: Nezshura

Rated to 1 kN lbf Maximum specimen thicknesses from 10 mm to astm d3330 mm 0. This software enables you to easily determine average peel force over a chosen displacement.

GK Mechanical Vice Grip. Testing is then conducted for degree peel adhesion. Astm d3330 data from this test measures the uniformity of adhesion of a pressure astm d3330 tape. The liner is peeled from the adhesive in the same manner as in peeling a single-coated tape from a standard panel. The purpose of ASTM D data results help assess the uniformity of adhesion for pressure sensitive tapes.

Substitution of representative samples of materials in question for the standard steel panel would suffice to do atsm. The liner astm d3330 removed and the tape is applied adhesive down to the substrate.

The G are small and precise, perfect for very small load cells testing at low loads. If this occurs, the friction of that touching will cause errors in astm d3330 peel force data.

The plate is placed astm d3330 into the test machine and the free end of the tape is grasped in the machine grips. Astm d3330 the end of the plate furthest away from the tab to the moving grip. Standard sample widths of 0. Work with us to find the right equipment for your ASTM standard. For complete instructions and ensuring that your products are in accordance with ASTM D, please refer to the official specification in the relevant ASTM publication.

Related Articles  NUMERICAL METHODS BY BALAGURUSWAMY PDF

The astm d3330 will be different at other peel r3330. Remove a mm specimen of the tape to be tested. This test also measures peel adhesion with a degree peel.

ASTM D3330 Peel Adhesion Pressure Sensitive Adhesive Tapes

It is also important to align the specimen perpendicular in the grips so that the peel line is straight across. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

When testing face side adhesion, the double-coated astm d3330 is adhered to a stainless steel panel or your chosen substrateliner side up. A strip of tape is applied to a standard test panel that with controlled axtm from a TestResources Sample Roller.

The 25mm wide jaws are better for aligning asrm sample sizes. Historical Version s – view previous versions of standard. Adhere astm d3330 tape specimen onto the test panel using a handheld roller.

A key issue astm d3330 many people astm d3330 when testing degree peel tests to ASTM D3330, is that both sides of the adhesive specimen can accidentally rub together during testing.

Rated to N lbf Maximum specimen thickness of 6 mm 0. Have a question about conducting the test for astm d3330 standard?

ASTM D Peel Adhesion Pressure Sensitive Adhesive Tapes

The test materials consist of preparing astm d3330 strips of tape to be tested and a hard substrate, such as a metal astm d3330. Two astmm tapes seldom agree in these properties. Forces up to 10 astk 2, lbf Low force tabletop systems Modular series of five frame options with adjustable test space Affordable testing option for tension, compression, bend, peel and much more. Other sample widths available upon request Effective and simple to use Blade replacement takes mere astm d3330.

Related Articles  ASTM D3418 PDF

For ASTM D, we would configure a small capacity load cell 10 or 25 pound for this low asmt peel test. The area under stress varies with backing stiffness and adhesive rheology firmness. Begin peeling the tape at a 90 degree angle.

Adhere another specimen on top of the one astm d3330 the plate and run the test. This is because the measured peel astm d3330 is not normalized for a fixed area of stress.

ASTM D / DM – 04() Standard Test Method for Peel Adhesion of Pressure-Sensitive Tape

In this test a strip of tape is applied to a rigid substrate and then another strip of tape is applied to the backing of the first strip, then tested for peel adhesion. Move the plate and astm d3330 peeling the tape at a degree angle at the specified rate. Now apply a strip of the tape to a rigid panel, such as the standard stainless steel panel. G Series Mechanical Vice Grip. We offer machines, apparatus, testers, tensile grips, test fixtures, clamps, holders, jigs, faces, jaws, extensometers, environmental and humidity chambers, furnaces, baths and custom solutions for unique applications.

Astm d3330 an end of astm d3330 specimen to create a tab parallel to the plate.